Easy resetting after activation
With no additional parts or service procedures required, PODx can be reset and reused quickly and efficiently on board the FPSO/AHT using standard tools: this can be done with or without the assistance of Gall Thomson.
Easy install and commissioning
PODx is simply installed between two shackles and no hot work or extensive drilling or fixing is required.
PODx can therefore be quickly fitted offshore when the FPSO or vessel is in the producing field.
PODx can also be retrofitted for permanent applications or for temporary short-term use.
Easy maintenance and operational monitoring
PODx offers minimum offshore maintenance and routine monitoring. The simple but ingenious design of PODx delivers extremely reliable performance and a long maintenance-free period of typically 36 months.
Lifespan of 25 years
The main components of PODx have an expected design life of 25 years.
Minimum deck footprint
Due to its compact and simple design, PODx offers a minimum footprint on FPSO and vessel decks. This is a major operational advantage over many alternatives.
Reliable
The PODx block is designed to enable the link to be released reliably at tensile loads above the yield point of the shackles in an emergency.
Robust
The PODx release bolt is enclosed within blocks. This makes the whole assembly very robust and suitable for the rigours of offshore operations.
No complicated monitoring system
The PODx is safe and simple to use. It can be supplied with a load monitoring shackle if required but is not supplied with an extensive load monitoring system.
Remote operation for maximum safety and control
PODx is activated using the Reflex HPU (R-HPU) which is located at a safe and convenient distance from where the mooring is released.
The Reflex R-HPU is a compact, pre-charged and low maintenance unit and provides a rapid hydraulic signal to PODx.
The HPU can be operated from a simple panel via pneumatic or electrical push buttons. This uses a stringent release sequence and is also equipped with mechanical interlocks to prevent accidental activation.
The integral control valve self-relieves the control lines. This compensates for temperature fluctuations while retaining hydraulic pressure stored within accumulators when in the dormant state.
Manual backup option
PODx can also be activated with a simple manual hand pump in case of complete FPSO/vessel blackout.
Safe release
The safety factor built in PODx is 5:1 and PODx includes a series of safety interlocks. This ensures unintentional release is impossible.